BQPDV - DRIVEWAY FILLER SEALER 052

  • MSDS: BQPDV
  • Manufacturer: GARDNER ASPHALT CORP
  • Product Name: DRIVEWAY FILLER SEALER 052
  • National Stock Number: 5610-00N012290
Product Identification

Product ID:DRIVEWAY FILLER SEALER 052
MSDS Date:08/01/1988
FSC:5610
NIIN:00N012290
MSDS Number: BQPDV

Responsible Party
GARDNER ASPHALT CORP
4161 E 7TH AVE
TAMPA, FL 33675
US

Emergency Phone: 813-248-2101

Info Phone: 813-248-2101

Cage: GARDN

Contractor
GARDNER ASPHALT CORP
5449 TAMPA, FL 33675-5449 US

Telephone: 813-248-2101

Cage: GARDN

Ingredients

RESIDUE DIFFICULT TO REMOVE. REFER TO REGULATIONS FOR

RTECS: 9999999ZZ

OSHA PEL N/K

ACGIH TLV: N/K


OVEREXP TO COAL TAR MAY

RTECS: 9999999ZZ

OSHA PEL N/K

ACGIH TLV: N/K


MUCOSA,SINUSES.RPTD/PRLNG CONT TO HI CONC MAY CAUSE

RTECS: 9999999ZZ

OSHA PEL N/K

ACGIH TLV: N/K


KNOWN TO CAUSE CANCER (CALIFORNIA

RTECS: 9999999ZZ

OSHA PEL N/K

ACGIH TLV: N/K


SPLASH GOGGLES. DO NOT

RTECS: 9999999ZZ

OSHA PEL N/K

ACGIH TLV: N/K


SILICA SAND (QUARTZ, CRYSTALLINE)

CAS: 14808-60-7

RTECS: VV7330000

Fraction By Weight: <25%

OSHA PEL SEE TABLE Z3

ACGIH TLV: 0.1 MG/M3 RDUST;9293


REFINED COAL TAR PITCH.COAL TAR PITCH VOLATILES (BENZENE

CAS: 8007-45-2

RTECS: GF8655000

Fraction By Weight: <15%

OSHA PEL 0.2 MG/M3

ACGIH TLV: 0.2 MG/M3


HYDROUS ALUMINUM SILICATE. OSHA PEL 5 MG/M3 RESP FRACTION.

CAS: 1332-58-7

RTECS: GF1670500

Fraction By Weight: <25%

OSHA PEL 15 MG/M3 TDUST

ACGIH TLV: 2 MG/M3 TDUST; 9293


PROPRIETARY SURFACTANT

Fraction By Weight: <1%

OSHA PEL N/K

ACGIH TLV: N/K


WATER

CAS: 7732-18-5

RTECS: ZC0110000

Fraction By Weight: >35%

OSHA PEL N/K

ACGIH TLV: N/K


CLEAN BEFORE REUSE. REMOVE CONTAM SHOES,

RTECS: 9999999ZZ

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:N/K
Routes of Entry: Inhalation:YES Skin:NO Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:PRLNG & RPTD CONTACT MAY CONTRIBUTE TO
CONDITIONS SUCH AS DERMATITIS, TAR WARTS. VAPORS AND MIST MAY CAUSE
KERATOCONJUNCTIVITIS AND POSSIBLE CORNEAL CHANGES. RPTD AND/OR
PRLNG CONTACT TO HIGH CONCENTR ATIONS AND INGESTION (IN EXTREME
CASES)MAY CAUSE CARDIOVASCULAR COLLAPSE. HARMFUL IF INHALED OR
SWALLOWED.
Explanation of Carcinogenicity:COAL-TAR PITCH VOLATILES:SUFF EVID FOR
CARC IN HUM (IARC,GROUP 1,1987). KNOWN HUMAN CARCINOGEN
(ACGIH,A1,1991). (SUPDAT)
Effects of Overexposure:EYES:VAP & MIST MAY CAUSE IRRIT TO EYES & MUC
MEM (BURNING
SENSATION,PHOTOPHOBIA,REDNESS,SWELLING,TEARING).SKIN:EXPOS CAUSES
IRRIT ACCENTUATED BY SUNLIGHT (ITCHING,BURNING,SWELLING,REDNESS).
PHOTOSENS ITIZATION MAY OCCUR.RPTD/PRLNG CONT (ROUGH
SKIN).INGEST:MAY CAUSE GI TRACT IRRIT (NAUS,VOM,ABDOM DISCOMFOR)
(SEE ING 8)
Medical Cond Aggravated by Exposure:PERSONS W/ HISTORY OF DISEASES IN
THE LIVER, SKIN,EYE,RESPIRATORY SYSTEMS,BLOOD FORMING ORGANS OR
BLEEDING ABNORMALITIES.THESE SYSTEMS ARE AT GREATER RISK THAN
NORMAL OF DEVELOPING ADVERSE HLTH EFTS.

First Aid

First Aid:EYES:IF CONT OCCURS FLUSH W/ WATER FOR AT LEAST 15 MINUTES &
SEEK MED ATTN.SKIN:IF CONT OCCURS,WASH AFFECTED AREA W/ WATERLESS
HAND CLEANER.REMOVE CONTAM CLTHG/SHOES.IF IRRIT PERSISTS,SEEK MED
ATTN.IN GEST:DO NOT INDUCE VOMITING.GIVE WATER/CLEAR
LIQUIDS.CONSULT LOCAL POIS CTL CTR IMMED.INHALATION:REMOVE TO FRESH
AIR.IF NOT BREATHING,GIVE ARTIFICIAL RESPIRATION OR OXYGEN AS
NEEDED.SEEK MED ATTN.

Fire Fighting

Flash Point Method:TCC
Flash Point:300F,148.9C MIN
Extinguishing Media:USE DRY CHEMICAL OR WATER FOG.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SCBA AND FULL
PROTECTIVE EQUIPMENT . WATER MAY BE USED TO KEEP FIRE EXPOSED
CONTAINERS COOL.
Unusual Fire/Explosion Hazard:DECOMPOSITION PRODUCTS UNDER FIRE
CONDITIONS:PYROLYSIS PRODUCTS OF AROMATIC HYDROCARBONS. WHEN
BURNED, TOXIC SMOKE AND VAPOR MAY BE EMITTED.

Accidental Release

Spill Release Procedures:LARGE SPILLS:EVACUATE ALL UNNECESSARY
PERSONNEL FROM AFFECTED AREA.DO NOT RE-ENTER AFFECTED AREA WITHOUT
PROPER PROTECTIVE EQUIPMENT.VENTILATE AREA OF SPILL.COLLECT IN MOST
SAFE MANNER FOR DISPOSAL OR RECLAMATION IN SEALED CONTAINERS.
Neutralizing Agent:N/K

Handling

Handling and Storage Precautions:KEEP ALL CONTAINERS TIGHTLY CLOSED AND
IN A PROPERLY VENTILATED AREA,AWAY FROM SOURCES OF HEAT AND FLAME.
Other Precautions:"EMPTY" CONTR RETAIN RESUDE (LIQ AND/OR VAP) & CAN BE
DANGEROUS.DO NOT PRESSURIZE,CUT,WELD,BRAZE,SOLDER,DRILL,GRIND/EXPOS
SUCH CONTRS TO HEAT,FLAME,SPK/OTHER SOURCES OF IGNIT,THEY MAY
EXPLODE & CAUSE INJURY/DEATH.DO NOT ATTEMPT (SEE ING 6)

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED RESPIRATOR WHEN TLV IS
EXCEEDED.
Ventilation:VENT SHOULD BE ADEQ.MAINTAIN VAPOR AND/OR PARTICULATE LEVEL
BELOW THE APPLIC EXPOS LIMITS FOR COAL TAR PITCH VOLATILES.
Protective Gloves:USE VITON OR POLYVINYL ALCOHOL.
Eye Protection:CHEM WORKERS GOG ./ (SEE ING 11)
Other Protective Equipment:EMPLOYEES WHO HAVE PRLNG/RPTD EXPOS SHOULD
WEAR GLOVES & LONG SLEEVED CLTHG IMPERVIOUS TO COAL TAR.REC
SUNBLOCK >30.
Work Hygienic Practices:IF HANDLE MATL CLEAN HANDS THORO BEFORE EATING/
SMKG.MINIMIZE BRTHG VAP/MIST.REMOVE CONTAM CLTHG,LAUNDER/DRY (SEE
ING 6)
Supplemental Safety and Health
BP:450-980F,232.2-526.7C.MP:POUR,CONGEALING/ MP >32F,0C.SPEC
GRAV:1.2-1.4,H2O=1.PH: 6.5-7.5.VISC:<8,000 CPS @ 77F,25C. VP:<1
MMHG @ 77F,25C.EXLAN OF CARCIN:PROCESS ASSOCIATED: KNOWN CARCIN
(NTP, GROUP 1). CRYSTALLINE SILICA QUARTZ:PROBABLYTO HUM
(IARC,GROUP 2A,1987). ANTICIPATED TO BE CARCIN (NTP,GROUP 2). (SEE
ING 1

Chemical Properties

HCC:T6
Boiling Pt:B.P. Text:SEE SUPP
Melt/Freeze Pt:M.P/F.P Text:SEE SUPP
Decomp Temp:Decomp Text:N/K
Vapor Pres:SEE SUPP
Vapor Density:>1 (AIR=1)
Spec Gravity:SEE SUPP
pH:SUP DA
Evaporation Rate & Reference:SLOWER THAN ETHER
Solubility in Water:PARTIALLY MISCIBLE
Appearance and Odor:A THICK, DARK BROWN TO BLACK COLORED MASTIC WITH A
COAL TAR PITCH ODOR.
Percent Volatiles by Volume:>35

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDANTS
Stability Condition to Avoid:HEAT, SPARKS, AND FLAME.
Hazardous Decomposition Products:WHEN BURNED, TOXIC SMOKE AND VAPOR MAY
BE EMITTED.
Conditions to Avoid Polymerization:WILL NOT OCCUR.

Disposal

Waste Disposal Methods:DISPOSAL MUST BE IN ACCORDANCE WITH
FEDERAL,STATE AND LOCAL REGULATIONS .

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.